0912-20-120VAC60C2
Pole Quantity: 1 Maximum Continuous Load Current Rating per Pole: 20.0 amperes ac single location Operating Voltage Type and Rating per Pole in Volts: 120.0 ac single location
Pole Quantity: 1 Maximum Continuous Load Current Rating per Pole: 20.0 amperes ac single location Operating Voltage Type and Rating per Pole in Volts: 120.0 ac single location ASAP can help source this line with documentation review, alternate part checks, condition requirements, and account manager follow-up for urgent or planned procurement.
Technical sourcing notes
Operations-grade aviation sourcing.
Request a quote for 0912-20-120VAC60C2
Send this part to ASAP with quantity, need-by timing, and buyer contact details. An account manager will review availability, alternates, certificates, and delivery options.
Submit RFQ for 0912-20-120VAC60C2
Send this part to ASAP with quantity, need-by timing, and buyer contact details. A dedicated account manager reviews availability, alternates, certificates, and delivery options.
- Manufacturer
- Leviton Manufacturing Co Inc
- CAGE
- 01643
NSN Information for Part Number 0912-20-120VAC60C2 with NSN 5925-00-982-6603, 5925009826603
Characteristics Data of NSN 5925-00-982-6603, 5925009826603
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | SINGLE POLE TYPE |
| ADAQ | BODY LENGTH | 3.365 INCHES MINIMUM AND 3.385 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 0.971 INCHES MINIMUM AND 0.991 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 2.334 INCHES MINIMUM AND 2.354 INCHES MAXIMUM |
| ADTV | CASE MATERIAL | PLASTIC |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJEC | BOSS HEIGHT | 0.146 INCHES MINIMUM AND 0.166 INCHES MAXIMUM |
| AKPX | POLE QUANTITY | 1 |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 CLAMP |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES AC SINGLE LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC SINGLE LOCATION |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC SINGLE LOCATION |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 5.500 MINIMUM AT 200 PCT SINGLE LOCATION AND 19.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT |
| FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 COMPRESSION |