Quote in 15 min·24/7 × 365AS9120:2025 · ISO 9001:2015 · FAA AC 00-56B
NSN 5930-00-583-1571CAGE 0TW10
17152-0
Switch Thermostatic
Switch Thermostatic ASAP can help source this line with documentation review, alternate part checks, condition requirements, and account manager follow-up for urgent or planned procurement.
Risco
Manufacturer
USA
Origin
N/A
Spec
N/A
Unit weight
Detailed description
Technical sourcing notes
N/A
Lead time
N/A
Cross references
Unrestricted
Export control
5930 Switches
FSC
Why ASAP
Operations-grade aviation sourcing.
AS9120B
Quality-managed distribution
15 min
Average RFQ response, 24/7
Full trace
Documentation & certs on request
Submit RFQ
Request a quote for 17152-0
Send this part to ASAP with quantity, need-by timing, and buyer contact details. An account manager will review availability, alternates, certificates, and delivery options.
Part-specific RFQ
Submit RFQ for 17152-0
Send this part to ASAP with quantity, need-by timing, and buyer contact details. A dedicated account manager reviews availability, alternates, certificates, and delivery options.
Switch Thermostatic17152-0
NSN5930-00-583-1571
- Manufacturer
- Risco
- CAGE
- 0TW10
NSN Information for Part Number 17152-0 with NSN 5930-00-583-1571, 5930005831571
Characteristics Data of NSN 5930-00-583-1571, 5930005831571
| MRC | Criteria | Characteristic |
|---|---|---|
| AAJD | THREAD CLASS | 3A SINGLE THREADED BUSHING |
| AASA | THREAD LENGTH | 0.188 INCHES NOMINAL SINGLE THREADED BUSHING |
| AWTN | OPERATING TEMP RATING | -100.0 DEG FAHRENHEIT MINIMUM AND 700.0 DEG FAHRENHEIT MAXIMUM |
| AXGY | MOUNTING METHOD | THREADED BUSHING |
| CMLP | THREAD QUANTITY PER INCH | 14 SINGLE THREADED BUSHING |
| CQGB | CONTACT ACTION STIMULUS | INCREASE |
| CQJX | NOMINAL THREAD SIZE | 0.750 INCHES SINGLE THREADED BUSHING |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| CSCF | TERMINAL TYPE | WIRE LEAD |
| CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 25.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET |
| CTYM | CONTACT ADJUSTMENT RANGE | -100.00/+300.00 ACTUATION POINT DEGREES FAHRENHEIT |
| CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW |
| CTYX | CONTACT STIMULUS RATING | 0.20 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL SECOND VOLTAGE |
| THSD | THREAD SERIES DESIGNATOR | UNC SINGLE THREADED BUSHING |